Products

    Reynaers CS 86-Hi

    CS 86-HI is a multi-chamber system for windows and doors that combines aesthetic design, optimal stability and high thermal comfort.

     

    Due to the insulating skeleton strips, CS 86-HI achieves Uf-values down to 1.2 W/m²K, making this a highly energy efficient system. Flexible expansion strips in the door vents ensure stability in all conditions.

     

    The system provides inside opening windows and inside & outside opening flush doors (up to 3 metres).

     

    Furthermore, CS 86-HI doors offer different types of floor connections to meet acoustic, thermal and water requirements.

    TECHNICAL CHARACTERISTICS

    Style variants

    FUNCTIONAL

    HIDDEN VENT

    Min. visible width inward opening window
    Frame 51 mm 70 mm
    Vent 35 mm not visible
     
    Min. visible width outward opening window
    Frame 68 mm  
    Vent 76 mm  
     

    Min. visible width inward opening flush door

    Frame 42 mm
    Vent 102 mm
     
    Min. visible width T-profile
      76 mm 95 mm
     

    Overall system depth window

    Frame 77 mm 77 mm
    Vent 86 mm 79 mm
     
    Rebate height 25 mm 17 mm
    Glass thickness up to 63 mm up to 44 mm
     
    Glazing method dry glazing with EPDM or neutral silicones
    Thermal insulation 41 mm fibreglass reinforced polyamide strips in skeleton structure or hollow chamber shape 32 mm (flexible) expansion strips
     
    PERFORMANCES

    ENERGY

    Thermal Insulation (1)

    EN 10077-2

     

    Uf-value between 1.6 W/m²K and 2.6 W/m²K,

    depending on the frame/vent combination

    COMFORT

    Acoustic performance (2)

    EN ISO 140-3; EN ISO 717-1

     

    Rw (C; Ctr) = 36 (-1; -4) / 42 (-2; -4) dB, depending on glazing type

    Air tightness, max. test pressure(3)

    EN 1026; EN 12207

    1

    (150 Pa)

    2

    (300 Pa)

    3

    (600 Pa)

    4

    (600 Pa)

    Water tightness  (4)

    EN 1027; EN 12208

    1A

    (0 Pa)

    2A

    (50 Pa)

    3A

    (100 Pa)

    4A

    (150 Pa)

    5A

    (200 Pa)

    6A

    (250 Pa)

    7A

    (300 Pa)

    8A

    (450 Pa)

    9A

    (600 Pa)

    E

    (900 Pa)

    Wind load resistance,

    max. test pressure (5)

    EN 12211; EN 12210

    1

    (400 Pa)

    2

    (800 Pa)

    3

    (1200 Pa)

    4

    (1600 Pa)

    5

    (2000 Pa)

    Exxx

    (> 2000 Pa)

    Wind load resistance to frame

    deflection  (5)

    EN 12211; EN 12210

    A

    (≤ 1/150)

     

    B

    (≤ 1/200)

     

    C

    (≤ 1/300)

     

    SAFETY

    Burglar resistance (6)

    ENV 1627 – ENV 1630

    WK 1

    WK 2

    WK

     

     

    (1) The Uf-value measures the heat flow. The lower the Uf-value, the better the thermal insulation of the frame.

    (2) The sound reduction index (Rw) measures the capacity of the sound reduction performance of the frame.

    (3) The air tightness test measures the volume of air that would pass through a closed window at a certain air pressure.

    (4) The water tightness testing involves applying a uniform water spray at increasing air pressure until water penetrates the window.

    (5) The wind load resistance is a measure of the profile’s structural strength and is tested by applying increasing levels of air pressure to simulate the wind

    force. There are up to five levels of wind resistance (1 to 5) and three deflection classes (A,B,C). The higher the number, the better the performance.

    (6) The burglar resistance is tested by statistical and dynamic loads, as well as by simulated attempts to break in using specified tools.

     

     