CS 77 is a thermally improved three-chamber system for windows and doors that boasts the optimum combination of safety and comfort.

 

Fibreglass reinforced polyamide strips with ribs and/or hollow chambers guarantee high thermal insulation levels.

 

The system is available in a variety of aesthetic shapes to match the current architectural trends whilst offering all types of both inward and outward opening windows and doors. A double butt strip between the frame and vent and a lowered drainage ensure superior wind and water tightness.

 

An additional asset of the system is the option to use it in combination with the Ventalis system. Different inner and outer colours are possible.

TECHNICAL CHARACTERISTICS

Min. visible width outward opening window

Style variants

FUNCTIONAL

HIDDEN VENT

Min. visible width inward opening window
Frame 51 mm 76 mm
Vent 33 mm not visible
 
Min. visible width outward opening window
Frame 17,5 mm
Vent 76 mm
 
Min. visible width inward opening flush door
Frame 67 mm
Vent 77 mm
 
Min. visible width outward opening flush door
Frame 42 mm
Vent 102 mm
 
Min. visible width T-profile
  76 mm 126 mm
 

Overall system depth window

Frame 68 mm 68 mm
Vent 77 mm 72,5 mm
 
Rebate height 25 mm 18,5 mm
Glass thickness up to 53 mm up to 49 mm
 
Glazing method dry glazing with EPDM or neutral silicones
Thermal insulation 32 mm omega-ribbed and/or hollow chamber-shaped fiberglass reinforced polyamide strips
 
PERFORMANCES

ENERGY

Thermal Insulation (1)

EN 10077-2

 

Uf-value between 1.6 W/m²K and 2.6 W/m²K,

depending on the frame/vent combination

COMFORT

Acoustic performance (2)

EN ISO 140-3; EN ISO 717-1

 

Rw (C; Ctr) = 36 (-1; -4) / 42 (-2; -4) dB, depending on glazing type

Air tightness, max. test pressure(3)

EN 1026; EN 12207

1

(150 Pa)

2

(300 Pa)

3

(600 Pa)

4

(600 Pa)

Water tightness  (4)

EN 1027; EN 12208

1A

(0 Pa)

2A

(50 Pa)

3A

(100 Pa)

4A

(150 Pa)

5A

(200 Pa)

6A

(250 Pa)

7A

(300 Pa)

8A

(450 Pa)

9A

(600 Pa)

E

(900 Pa)

Wind load resistance,

max. test pressure (5)

EN 12211; EN 12210

1

(400 Pa)

2

(800 Pa)

3

(1200 Pa)

4

(1600 Pa)

5

(2000 Pa)

Exxx

(> 2000 Pa)

Wind load resistance to frame

deflection  (5)

EN 12211; EN 12210

A

(≤ 1/150)

 

B

(≤ 1/200)

 

C

(≤ 1/300)

 

SAFETY

Burglar resistance (6)

ENV 1627 – ENV 1630

WK 1

WK 2

WK

 

 

This table shows possible classes and values of performances. The values indicated in red are the ones relevant to this system.

(1) The Uf-value measures the heat flow. The lower the Uf-value, the better the thermal insulation of the frame.

(2) The sound reduction index (Rw) measures the capacity of the sound reduction performance of the frame.

(3) The air tightness test measures the volume of air that would pass through a closed window at a certain air pressure.

(4) The water tightness testing involves applying a uniform water spray at increasing air pressure until water penetrates the window.

(5) The wind load resistance is a measure of the profile’s structural strength and is tested by applying increasing levels of air pressure to simulate the wind force.

There are up to five levels of wind resistance (1 to 5) and three deflection classes (A,B,C). The higher the number, the better the performance.

(6) The burglar resistance is tested by statistical and dynamic loads, as well as by simulated attempts to break in using specified tools.

 

 